2025-09-30 16:43 UTC
@twosky2000 @timonsku @alvaro The problem is the short across the CC lines at the sink causes the source to see the sink-side 1k resistor on the opposite CC line on an e-marked cable
Replies (1)
-
@wren6991@types.pl 2025-09-30 16:44
@twosky2000 @timonsku @alvaro You can't see the problem in this diagram because this type of cable works fine. You need to look at the e-marked cable diagram in Alvaro's blog post